xan_black
Providing Real-Time Simulation and Test Systems for over 20 Years

> [Home]  > [Products]  > [Hardware]  > [RT-RUG]  > [Specifications]

RT-RUG Specifications

 

Contact us today so our simulation engineers
can assist you from the beginning.

Processor

x86 compatible 850 MHz Clock (upgradeable)

256 MB RAM

Analog Input

16 single-ended / 8 differential analog inputs 12-bit resolution
10 kHz absolute maximum sample rate

Analog Output

12 D/A channels 12-bit resolution (1 in 4096)
Switch selectable output ranges
One D/A per channel Output ranges: ±10V, ±5V, 0-10V, 0.5V Output current: ±5mA min.
Output resistance: <0.1Ohm
Short circuit current: 40mA min.
Range selection: Switch selectable
Output setting: (to 0.003%) 5µs typ., 10µs max.
Output updates: Independent or simultaneous

Digital and Serial I/O

24-bits of digital I/O

RS-232 Synchronous or Asynchronous

Synchro Generation and Input

Frequency and Reference Voltage can be tailored to fit the customers needs.
4 Channels Input
4 Channels Output

Chassis

Mechanical Shock Testing:
       Pulse Shape - Half Sine wave
       18  (3 each, plus or minus, in X, Y, and Z Coordinates)
       10 G Vertical Shock, 7 G horizontal Shock
       Duration: 40 ms
       Power not applied to the system.

Mechanical Vibration Testing:
A. Exploratory:  (12 Minutes)
       5 to 33 Hz at .01 inch single amplitude
       34 to 50 Hz at .003 inch single amplitude

B. Variable Frequency:
       46 Increments in 1 Hz Steps

C. Dwell:  (60 Minutes)
       At Resonance
 

EMI (emission and susceptivity) characteristics shall not exceed the limits specified in MIL-STD-461D for the MIL-STD-462 test methods as applicable to class a4 equipment.


[Home] [About] [Contact Us] [Products] [Support] [Free Software] [FAQ]

Copyright 1992-2007 XANALOG Corporation
Questions about the Site?
E-mail the Webmaster